Study summary
How AlphaPWR measurements compared with a laboratory reference
- Measurement validity
In brief
This evaluation compared concurrent AlphaPWR and laboratory-reference measurements during countermovement jumps. Across 124 analysed jumps, the reported mean biases were small for the assessed metrics. Jump height differed by -0.22% on average, while mean and peak force differed by approximately 1.1% and 1.17% respectively.
What was studied
Five recreational athletes completed countermovement jumps with AlphaPWR positioned over an in-ground AMTI reference system. The analysis included 124 matched jumps plus a separate calibrated static-load comparison.
What the source reported
- 01
The reported mean bias for jump height was -0.06 cm, or -0.22%.
- 02
Mean force and peak force showed reported mean biases of 1.1% and 1.17%.
- 03
The paper reported small typical errors and trivial effect sizes across the assessed metrics.
How to interpret the findings
The participant sample was small and the evaluation focused on one jumping protocol. The results support the reported metrics in this setup, not every activity or software output produced by the platform.
Source details
- Author(s)
- Lisa Kristin Dahle, Manuel Alfaro, Gøran Paulsen
- Institution
- Norwegian School of Sport Sciences
- Year
- 2024
- Document type
- Evaluation study
- Length
- 5 pages
- Source language
- English
The PDF is provided from the source file linked to this record.